719
SET Titrino |
702
SM Titrino |
718
STAT Titrino |
794
Basic Titrino |
798
MPT Titrino |
799
GPT Titrino |
787
KF Titrino |
795
KFT Titrino |
758
KFD Titrino |
|
|
|
|
|
|
|
|
|
|
| Real-time
curve display with graphics LCD |
- |
- |
- |
- |
yes |
yes |
- |
yes |
yes |
| Determination
Modes |
|
|
|
|
|
|
|
|
|
| DET:
Dynamic Endpoint Titration |
- |
- |
- |
yes |
yes
|
yes |
- |
- |
- |
| MET:
Monotonic Endpoint Titration |
- |
yes
|
- |
yes
|
yes
|
yes |
- |
-
|
- |
| SET:
titration to preset endpoints |
yes |
yes
|
yes
|
yes
|
yes
|
yes
|
-
|
-
|
yes |
KFT:
Karl
Fischer Titrations |
-
|
- |
- |
- |
- |
yes |
yes |
yes
|
yes |
| STAT:
pH/mV stat titration |
- |
- |
yes |
- |
- |
yes
|
- |
-
|
- |
| DOC
controlled dispensing, measured value/time gradients |
- |
- |
yes |
- |
- |
yes
|
- |
-
|
- |
| DOS
Dispensing of liquids with monitoring |
- |
- |
yes |
- |
- |
yes
|
- |
-
|
- |
| MEAS:
pH/mV/temp. measurement |
yes |
yes
|
yes
|
yes
|
yes
|
yes
|
-
|
-
|
yes |
| CAL:
Calibration with pH buffer solutions |
yes |
yes
|
yes
|
yes
|
yes
|
yes
|
-
|
-
|
yes |
| TIP
method linking |
- |
- |
yes |
yes |
yes
|
yes
|
- |
-
|
yes
|
| Determination
of pK value |
- |
- |
- |
yes |
yes
|
yes |
- |
-
|
- |
| Minimum-maximum
evaluation |
-
|
- |
- |
- |
yes |
yes |
- |
-
|
- |
|
|
|
|
|
|
|
|
|
|
|
719
SET Titrino |
702
SM Titrino |
718
STAT Titrino |
794
Basic Titrino |
798
MPT Titrino |
799
GPT Titrino |
787
KF Titrino |
795
KFT Titrino |
758
KFD Titrino |
|
|
|
|
|
|
|
|
|
|
| Hardware |
|
|
|
|
|
|
|
|
|
| Ipol
& Upol: integrated programmable polarizer |
yes
|
yes
|
yes
|
yes
|
yes
|
yes
|
yes
|
yes
|
yes
|
| Number
of high-impedance measuring inputs |
2
|
2 |
2 |
2 |
2 |
2 |
- |
-
|
2 |
| Differential
potentiometry |
yes |
yes
|
yes
|
yes
|
yes
|
yes
|
-
|
-
|
yes
|
| Number
of dialog languages |
7 |
7 |
7 |
7 |
7 |
7 |
4 |
7 |
7 |
| Data
Handling |
|
|
|
|
|
|
|
|
|
| SILO
memory for methods and sample data |
yes |
yes
|
yes
|
yes
|
yes
|
yes
|
- |
yes
|
yes
|
| Result
memory |
- |
- |
yes |
yes |
yes
|
yes
|
- |
yes
|
yes
|
| Memory
cards for user methods (compatible with each other) |
- |
- |
- |
- |
yes |
yes |
- |
-
|
yes
|
| Ready-to-use
titration methods (stored on a read-only memory card or in the Titrino) |
yes |
yes |
yes |
yes |
yes
|
yes
|
yes |
yes
|
yes
|
| User
name list |
- |
- |
- |
- |
yes
|
yes
|
- |
yes
|
yes
|
| Monitoring
of validation interval |
- |
- |
- |
- |
yes
|
yes
|
- |
yes
|
yes
|
| Monitoring
of service interval |
- |
- |
- |
- |
yes |
yes |
- |
yes
|
yes
|
| Monitoring
of calibration interval |
- |
-
|
-
|
-
|
yes |
yes
|
-
|
-
|
yes
|
| Monitoring
of sample size limits |
-
|
-
|
-
|
-
|
yes
|
yes
|
- |
yes
|
yes
|
| Monitoring
of result limits |
- |
-
|
-
|
-
|
yes
|
yes
|
- |
yes
|
yes
|
| System
test report |
- |
- |
- |
- |
yes |
yes |
- |
yes |
yes |
| Oven
parameters in the result report |
- |
- |
- |
- |
- |
yes |
- |
yes |
yes |
| Interfaces |
|
|
|
|
|
|
|
|
|
Number
of RS 232C interfaces for printer, PC, balance
|
1 |
1 |
1 |
1 |
2 |
2 |
1 |
2 |
2 |
| Connection
of PC keyboard and barcode reader |
- |
- |
- |
- |
yes |
yes |
- |
yes |
yes |
| Two
additional dispensing units (765/776) for auxiliary solutions |
yes |
yes |
yes |
yes |
yes |
yes |
- |
yes |
yes |
| Two
additional dispensing units (685/700) for titrants |
- |
- |
- |
- |
- |
yes |
- |
- |
yes |
| Stirrer
connection |
yes |
yes |
yes |
yes |
yes |
yes |
yes |
yes |
yes |
| Stirrer
control |
- |
- |
- |
- |
yes |
yes |
- |
yes |
yes |
| Sample
changer connection |
yes |
yes |
yes |
yes |
yes |
yes |
- |
yes |
yes |
| KF
oven connection |
- |
- |
- |
- |
- |
yes |
yes |
yes |
yes |
| PC
Software |
|
|
|
|
|
|
|
|
|
| Compatible
with TiNet 2.5 |
yes |
yes |
yes |
yes |
yes |
yes |
- |
yes |
yes |
| VESUV
3.0 Light included |
yes |
yes |
yes |
yes |
yes |
yes |
yes |
yes |
yes |
|
|
|
|
|
|
|
|
|
|
|
719
SET Titrino |
702
SM Titrino |
718
STAT Titrino |
794
Basic Titrino |
798
MPT Titrino |
799
GPT Titrino |
787
KF Titrino |
795
KFT Titrino |
758
KFD Titrino |
|
|
|
|
|
|
|
|
|
|
|