Sophisticated
construction
|
The
832 KF Thermo Prep has been developed from the conventional tube
oven. However, instead of introducing the sample into the oven by
means of a sample boat, the vial technique is used, i.e. the sample
is weighed directly into the sample vial, sealed and transferred
to the oven. The 832 KF Thermo Prep is a very compact instrument.
Heating block, gas pump, flow meter and flow controller are all
integrated, as are the drying flasks.
|
|
832
KF Thermo Prep with 728 Magnetic stirrer, 831 KF Coulometer and
accessories
|
 |
|
No
side reactions
|
-
Strictly
reproducible analysis conditions yield results with markedly
improved precision
-
Manual
sample preparation is reduced to a minimum
-
You
achieve considerable time savings
-
There
is no contamination of the oven and the titration cell; consequently
there are no carryover and memory effects
-
The
reagent consumption diminishes significantly as the titrant
has to be exchanged only infrequently
-
Water
release from the sample improves as the carrier gas does not
just pass over the sample but directly through it
-
Accommodates
any size of sample vessel
|
| Any
size of sample vessel |
The oven's construction is so flexible that you can use
not only the Metrohm standard sample vials but also those used in
your production plant.
|
| Easy
sample preparation |
Sample preparation
is straightforward and consists of weighing the sample into the
sample vial, which is then sealed using the crimping tool. The hermetic
sealing of the vials by the PTFE-covered septa reliably prevents
any interference by moisture uptake from ambient air.
Moreover, contamination
and carryover effects are absent as each sample is introduced into
its own sample vial and stays there during the determination as
only the water to be determined is transferred to the titration
cell.
|
| Refined
methodology |
The vial containing
the sample to be analyzed is positioned above the oven and lowered
into the heating block. At the same time a double hollow needle
pierces the vial's septum. Via the inlet needle the carrier gas
stream is passed through the heated sample. The carrier gas, loaded
with the released moisture, passes through the outlet needle into
a tube and then directly into the titration cell.
Depending on
the sample's water content, the subsequent KF water determination
can be carried out volumetrically or, in the trace region,
coulometrically.
|
|
If you wish
to get more information on the 832 Thermo Prep you may either submit
our reply form or send an e-mail to Chennai@mdml.com.
|